Test protocols have been developed to test water treatment devices/systems for use for treating drinking water that are used at the individual and home level to ensure the removal of waterborne viruses. Current test procedures call for the use of poliovirus type 1 and/or rotavirus SA11. Recently we suggested that selected coliphages could be used as surrogates for poliovirus for testing of point-of-use (POU) water treatment devices, however, rotavirus was not used in those studies. The purpose of this review was to compare studies of POU devices which were tested with poliovirus type 1, simian rotavirus SA11 and coliphage MS2 to determine if the behavior of rotavirus SA11 was significantly different. In addition, an attempt was made to compare the relative resistance of these viruses by various disinfectants used to treat drinking water. In all cases SA11 was removed to an equal or greater degree than poliovirus. SA11 was found to be less resistant to halogens, although one study found it to be more resistance to chloramines than poliovirus and MS2. Based on this review, use of coliphages for testing POU devices appear justified. Additionally, data on chloramines for these viruses would be useful to determine if rotavirus is more resistant than poliovirus and MS2.