Abstract The evaluation and usefulness of lightning prediction for the Indian subcontinent are demonstrated. Implementation of the lightning parameterizations based on storm parameters, in the Weather Research and Forecasting (WRF) Model, with different microphysics schemes are carried out. With the availability of observed lightning measurements over Maharashtra from the lightning detection network (LDN), lightning cases have been identified during the pre-monsoon season of 2016–18. Lightning parameterization based on cloud top height defined by a reflectivity threshold factor of 20 dBZ is chosen. Initial analysis is carried out for 16 lightning events with four microphysical schemes for the usefulness in lightning prediction. Objective analysis is carried out and quantitative model performance (skill scores) is assessed based on observed data. The skills are evaluated for 10- and 50-km2 boxes from the 1-km domain. There is good POD of 0.86, 0.82, 0.85, and 0.84, and false alarm ratio (FAR) of 0.28, 0.25, 0.29, and 0.26 from WSM6, Thompson, Morrison, and WDM6, respectively. There is an overestimation in lightning flash with a spatial and temporal shift. The fractional skill score is evaluated as a function of spatial scale with neighborhoods from 25 to 250 km. These high skill scores and high degree of correlation between observations and model simulation gives us confidence to use the system for real-time operational forecast over India. The skill for 2019 and 2020 pre-monsoon are calculated to address the predictability of operational lightning prediction over India. Significance Statement A high-resolution model, namely, the Weather Research and Forecasting (WRF) Model, with multiple microphysics parameterization schemes and lightning parameterization is used here. The objective analysis is carried out for the lightning cases over India and the quantitative performance is assessed. The results highlight that there is fairly good probability of detection (POD) of 0.86, 0.82, 0.85, and 0.84 and false alarm ratio (FAR) of 0.28, 0.25, 0.29, and 0.26 from four different microphysical schemes (WSM6, Thompson, Morrison, and WDM6, respectively). These high skill scores and high degree of correlation between observations and model simulation gives us confidence to use the system for real-time operational forecast. The validation of lightning forecast system deployed over India for five pre-monsoon months in real time is carried out, which gives POD of 0.90, FAR of 0.64, hit rate of 0.57, and POFD of 0.50 for the whole Indian region.
Read full abstract