SARS-CoV-2 is primarily a respiratory virus that can potentially be transmitted through fomites. Sodium hypochlorite (NaOCl) and peracetic acid (PAA) are widely used disinfectants on surfaces in diverse settings such as hospitals and food production facilities. The objectives of this study were to investigate the virucidal efficacy of NaOCl and PAA against SARS-CoV-2 using the ASTM standard methods. In the suspension assay, NaOCl and PAA (5, 50, and 200 ppm) were tested against SARS-CoV-2 in the presence/absence of soil load after 1 min of contact time. In the carrier assay, NaOCl and PAA were tested at 200, 400, 600, and 1,000 ppm for 1 min and 200 and 1,000 ppm for 5 and 10 min. Stainless steel (SS) and high-density polyethylene (HDPE) disks were used as carriers. The virus was suspended in soil load and the disinfectants were prepared in 300 ppm of hard water. Virus quantification was done by TCID50 assay using Vero-E6 cell line. NaOCl and PAA were effective (> 3 log reduction in infectious virus) at 50 ppm in the absence of soil load. However, in the presence of soil load, 200 ppm was required for > 3 log reduction in virus infectivity. In contrast, NaOCl and PAA at 200 ppm and with a 1-min contact time were not effective against SARS-CoV-2 on either SS or HDPE surfaces. PAA at 200 ppm for 10 min was effective against SARS-CoV-2 on SS and HDPE surfaces, whereas NaOCl required 1,000 ppm for 10 min to be effective against SARS-CoV-2 on both surfaces. IMPORTANCE In the context of the COVID-19 pandemic, the World Health Organization (WHO) recommended the use of chlorine-based products such as sodium hypochlorite (NaOCl) at 1,000 ppm for a minimum of 1 min to disinfect environmental surfaces. However, this recommendation was not based on validated studies on the actual SARS-CoV-2 itself. In fact, over half of the chemical disinfectants, including many peracetic acid products, listed in EPA List N were approved based on "kills a harder-to-kill pathogen" without further validation on SARS-CoV-2. Research on SARS-CoV-2 is restricted to BSL3 laboratories and the urgency of tackling the pandemic might explain the lack of studies on the actual virus. Our results show that the WHO recommendation of 1 min contact time with 1,000 ppm NaOCl is not effective against SARS-CoV-2 on surfaces. Also, our results indicate that PAA is effective against SARS-CoV-2 on surfaces and can be used as safer and more environmentally friendly alternative to NaOCl at a lower concentration.