Water within flooded coal mines can be abstracted via boreholes or shafts, where heat can be extracted from (or rejected to) it to satisfy surface heating (or cooling) demands. Following use, water can be reinjected to the mine workings, or discharged to a surface water receptor. Four criteria have been applied, using ArcGIS, to datasets describing mine workings and mine water below the Midland Valley of Scotland, to provide an initial screening tool for suitability for mine water geothermal energy exploitation. The criteria are: (i) presence of two or more worked coal seams below site, (ii) absence of potentially unstable shallow (<30 m) workings, (iii) depth to mine water piezometric head <60 m, (iv) depth of coal mine workings <250 m. The result is the Mine Water Geothermal Resource Atlas for Scotland (MiRAS). MiRAS suggests that a total area of 370 km 2 is “optimal” for mine water geothermal development across 19 local authority areas, with greatest coverage in North Lanarkshire. This result should not be taken to suggest that mine water geothermal potential does not exist at locations outside the identified “optimal” footprint. The MiRAS does not preclude the necessity for specialist engineering and geological input during full feasibility study. Thematic collection: This article is part of the Mine Water Energy collection available at: https://www.lyellcollection.org/topic/collections/mine-water-energy Supplementary material: https://doi.org/10.6084/m9.figshare.c.7235866