The challenges faced in an isolated wind energy conversion system (WECS) are larger transient times, high steady-state error, and larger harmonic content. To overcome these issues, an adaptive voltage controller (AVC) along with the load current observer (LCO) could be the better proposition. However, the AVC and LCO, in conjunction with the conventional space vector pulse width modulation (SVPWM) technique to operate the three-phase inverter of WECS, would not be able to further improve these parameters. This paper proposes the use of the unified voltage SVPWM (UVSVPWM) technique along with the AVC and LCO, which could improve the transient behavior by about 30% as well as reduce the harmonic content of the load voltage and current by about 70% and 2%, respectively. This paper considers an isolated WECS connected to the linear load, which is operated under balanced as well as unbalanced load conditions. The proposed control technique is verified for both the balanced and unbalanced cases using MATLAB/Simulink.
Read full abstract