The mechanical system applied in industry and manufacturing fields is generally a complex multi-stage isolation system, which contains a lot of connection parts. In order to better analyze the effect of the connection parts, the transfer path model of a two-stage serial system is developed in this article using frequency response function based substructuring method. To verify the proposed transfer path model, a finite element model that simulates a two-stage serial vibration isolation system is built. By comparing the predicted results and exact values, the model proves to be correct. Furthermore, the random noise is introduced into the system-level frequency response functions for error sensitivity analysis and the influence on the substructure frequency response functions is quantified through comparison. Since the possible errors are unknown in the experimental measurement, 5%, 25%, and 50% random errors are introduced into all the input frequency response functions individually to analyze the influence of different noise levels on the prediction accuracy. In order to solve the ill-conditioned inverse problem involved in the model, the truncated singular value decomposition is also applied. The simulation results show that compared with the direct-inverse method, truncated singular value decomposition can decrease the prediction error caused by the introduced noise more effectively.