Bronchoscopy is an aerosol-generating procedure and can place the health care providers at risk for exposure to viral pathogens. The pattern of aerosol generation during different aspects of bronchoscopy are poorly understood. The goal of this study is to characterize the pattern of aerosol generation during flexible and rigid bronchoscopy performed under moderate sedation or general anesthesia (GA). The inhalable mass concentration of aerosol generated during the procedures was measured continuously. The aerosol concentration in the endoscopy room at baseline and while the procedures were performed was measured. Procedures included flexible bronchoscopies with moderate sedation, flexible bronchoscopies performed through endotracheal tube under GA and rigid bronchoscopies under GA. Changes from the baseline were measured continuously during the bronchoscopy. Measurements obtained during the procedure were compared with the baseline reading. For flexible bronchoscopy under moderate sedation, the inhalable aerosol fraction was significantly higher (P=0.036) during atomization of lidocaine. For Flexible bronchoscopy through endotracheal tube, inhalable aerosol fraction was significantly higher (P<0.001) during intubation and extubation. For rigid bronchoscopy done under GA with jet ventilation, inhalable aerosol fraction was significantly higher during both the bronchoscopy (P=0.01) and recovery (P=0.012). Elevated levels of aerosol were generated during all aspects of bronchoscopy. However, atomization of lidocaine, intubation, extubation, and recovery generated the most aerosol.