This contribution presents new DC–DC Boost and Buck-Boost converter topologies to track sinusoidal signals in an exact form, that is, with zero error tracking. The proposed topology considers two DC–DC converters connected to the same load, which means that the converters are not in a cascade connection. To track the exact sinusoidal reference, the control algorithm is based on the indirect control algorithm and the harmonic balance method. The main contribution is to consider two control inputs that facilitate and permit canceling out the second harmonic generated by the nonlinearity of the model, and as a result there is a single frequency in the output. The result is such that the converters can track sinusoidal signals with exactly zero error. With this, there is a reduction in the potential negative effects on systems and equipment; some numerical results are presented to corroborate the proposal.
Read full abstract