BackgroundAcetabular dysplasia has been theorized as a risk factor instability amongst common acetabular fractures, such as posterior wall (PW) fractures. However, common radiographic measurements often cannot be acquired in trauma patients. We evaluated axial computed tomography (CT) scans to identify novel, easily-obtained measurements that correlate with acetabular dysplasia for use in surgical indications and planning. MethodsPatients with known acetabular dysplasia undergoing elective periacetabular osteotomy were selected. A different group of patients without pelvic ring or acetabular fractures from an institutional trauma registry were selected as a comparison group. Standard indices of dysplasia were collected, such as center-edge angle (CEA). Acetabular geometric measurements were taken at three axial levels: 0 – cranial CT slice at the dome; 1 – cranial CT where the dome is an incomplete circle; 2 – cranial CT with femoral head visible. Distances between levels were also calculated: Levels 0–1 (Dome Height; DH), Levels 1–2 (Head Height; HH), and Dome-Head Difference (DH – HH = DHD). ResultsDH, HH, and DHD were all significantly correlated with CEA, Tonnis angle, and Sharp's angle in dysplastic hips. All dysplastic hips had DH ≤ 2.5 mm and HH ≥ 1.25 mm. DHD ≤ 0 mm was most specific (93.6 % sensitive, 77.3 % specific) for predicting dysplasia. ConclusionDH ≤ 2.5 mm, HH ≥ 1.25 mm, and DHD ≤ 0 mm were independently associated with dysplasia on axial CT scans. These measurements may be quickly and easily used by trauma surgeons to assess a trauma-based axial CT scan for acetabular dysplasia.