This pilot study assessed the 12-month angiographic and clinical outcomes of self-apposing (SA) stents in patients undergoing chronic total occlusion (CTO) percutaneous coronary intervention (PCI). Self-apposing (SA) stents may decrease incomplete strut apposition and stent strut coverage that are common after CTO PCI. We compared 20 patients who underwent CTO PCI using SA drug-eluting stents (DESs) with 20 matched control patients who underwent CTO PCI using balloon-expandable (BE)-DESs. All patients were followed up clinically for 12 months and had coronary angiography with optical coherence tomography at the end of the follow-up period. The primary end points were stent strut malapposition and strut coverage. The secondary end point was composite major adverse cardiovascular events (MACEs) at 12 months. Both groups had high prevalence of diabetes mellitus, and most of the treated lesions were complex, with 62% having a J-CTO score of ≥3. All CTO PCI techniques were allowed for recanalisation, and 75% of the procedures were guided by intravascular ultrasound. At 12 months, the SA-DES group had fewer malapposed struts (0% [interquartile range (IQR) 0%-0%] vs 4.5% [IQR 0%-20%]; p<0.001) and uncovered struts (0.08% [IQR 0%-1.6%] vs 8.2% [IQR 0%-16%]; p<0.001). However, they showed significantly higher rates of MACEs due to clinically-driven target lesion revascularisation (45% vs 15%; p=0.038). In this pilot study, compared with conventional BE-DESs, SA-DESs used in CTO PCI were associated with fewer malapposed and uncovered stent struts but also with significantly higher rates of in-stent restenosis and MACEs, mainly caused by clinically driven target lesion revascularisation.