The incidence of osteoporotic pelvic fractures is increasing. The broken anterior pelvic ring is preferentially fixed with long intramedullary screws, which require a good understanding of the patient-specific anatomy to prevent joint perforation. The aim of this study was to assess the variability of the superior pubic ramus and the supra acetabular corridors' length and width using statistical shape modelling. A male and female statistical shape model was made based on 59 forensic CT scans. For the superior pubic ramus and the supra acetabular corridor the longest and widest completely fitting cylinder was created for the first 5 principal components (PC) of both models, male and female pelvises separately. A total of 59 pelvises were included in this study of which 36 male and 23 female. The first 5 principal components explained 75% and 79% of the pelvic variation in males and females, respectively. Within 3 PCs of the female statistical shape model (SSM) a superior pubic ramus corridor of < 7.3mm was found, 5.5mm being the narrowest linear corridor measured. Both corridors in all PCs of the male SSM measured > 7.3mm. Within females a 7.3mm and 6.5mm screw won't always fit in the superior pubic ramus corridor, especially if a flat sacrum, a small pelvis or a wide subpubic angle are present. The supra acetabular corridor did not seem to have sex-specific differences. In the supra-acetabular corridor there was always enough space to accommodate a 7.3mm screw, both in males and females.