It is a known fact that the world's dependence on electrical energy is increasing day by day. The fact that electrical energy has some advantages over other types of energy, the increasing world population and changing living conditions can be considered among the reasons for this increase. This increase in dependence on electrical energy can be met by expanding existing facilities and establishing new facilities. In these studies, the transmission of electrical energy from the place where it is produced to the place where it is consumed poses important problems as the system expands. Some work is required to eliminate these technical and economic problems and to ensure stable operation of the system. These are problems that were not considered beforehand as the system grew. One of these problems is the ferroresonance phenomenon that occurs at the fundamental frequency due to the nonlinear magnetization characteristics of transformers. Ferroresonance is a resonance phenomenon that occurs in an electrical circuit containing an iron-core self-coil as a nonlinear element. This resonance manifests itself with sudden oscillations in the output size of the system caused by a small change in the amplitude or frequency of a magnitude applied to the input of the system. High voltage transmission lines are double-circuit lines that share the same pole. In special cases such as maintenance or malfunction of such a transmission system, one of the lines can be disconnected from the system and continue energy transmission with the other line. In the high voltage transmission line, the system may oscillate due to the stored energy in the magnetic field of the transformer inductance on the disabled line and the electric field of the line capacity. This oscillation disappears after a certain period of time due to iron losses and other circuit losses. When these losses are covered by the other transmission line, permanent oscillations and over voltages may occur at the transformer terminals. All these events are the negative effects of ferroresonance on transmission systems. In the energy transmission system, ferroresonance phenomenon occurs. Over voltages may occur in case of idle power transformers in star point/isolated networks. In medium voltage networks, ferroresonance occurs due to the melting of a fuse, the opening and closing of voltage transformers with one pole, and the dissymmetry that occurs as a result of a connection process. These negative effects caused by ferroresonance in the energy transmission power system are discussed in detail within the subject of this study.
Read full abstract