The aim of this prospective cohort study was to assess the facial-palatal ridge dimensional changes that occurred at 8-10 months following flapless dual-zone (DZ) immediate implant placement and socket-shield (SS) immediate placement in the maxilla. A total of 19 patients who received 20 implants were included, with 10 implants (MegaGen AnyRidge) placed for each treatment, DZ and SS. Cast models were made at 8-10 months after implant placement to assess the dimensional ridge changes by measuring the facial-palatal ridge width on implant sites (T) at six designated points starting from the gingival margin (0, 1, 2, 3, 5 and 7) and comparing it with the corresponding measurement on the contralateral tooth site (C). All 20 implants demonstrated successful osseointegration at 8-10 months follow-up (survival rate 100%). Two out of ten cases of SS group presented with minor manageable complications of external shield exposure. DZ group showed an average of 0.3 mm facial-palatal ridge width reduction, while SS group revealed a mean gain in ridge width of approximately 0.2 mm at 8-10 months follow-up. When comparing between two treatments, there was a significant difference in ridge width change at 8-10 months following implant placement, indicating better preservation of the ridge contour for socket shield technique.