Metallic bioresorbable orthopaedic implants based on magnesium, iron and zinc-based alloys that provide rigid internal fixation without foreign-body complications associated with permanent implants have great potential as next-generation orthopaedic devices. Magnesium (Mg) based alloys exhibit excellent biocompatibility. However, the mechanical performance of such implants for orthopaedic applications is contingent on limiting the rate of corrosion in vivo throughout the bone healing process. Additionally, the surgical procedure for the implantation of internal bone fixation devices may impart plastic deformation to the device, potentially altering the corrosion rate of the device. The primary objective of this study was to develop a computer-based model for predicting the in vivo corrosion behaviour of implants manufactured from a Mg-1Zn-0.25Ca ternary alloy (ZX10). The proposed corrosion model was calibrated with an extensive range of mechanical and in vitro corrosion testing. Finally, the model was validated by comparing the in vivo corrosion performance of the implants during preliminary animal testing with the corrosion performance predicted by the model. The proposed model accurately predicts the in vitro corrosion rate, while overestimating the in vivo corrosion rate of ZX10 implants. Overall, the model provides a “first-line of design” for the development of new bioresorbable Mg-based orthopaedic devices. Statement of significanceBiodegradable metallic orthopaedic implant devices have emerged as a potential alternative to permanent implants, although successful adoption is contingent on achieving an acceptable degradation profile. A reliable computational method for accurately estimating the rate of biodegradation in vivo would greatly accelerate the development of resorbable orthopaedic implants by highlighting the potential risk of premature implant failure at an early stage of the device development. Phenomenological corrosion modelling approach is a promising computational tool for predicting the biodegradation of implants. However, the validity of the models for predicting the in vivo biodegradation of Mg alloys is yet to be determined. Present study investigates the validity of the phenomenological modelling approach for simulating the biodegradation of resorbable metallic orthopaedic implants by using a porcine model that targets craniofacial applications.