In the last decades technological advances are increasing with the development of new treatment techniques and ways to deliver cranial radiosurgery(SRS), that is based into precision and accuracy, Volumetric Arc Therapy (VMAT) have been used in brain radio surgery in terms of non coplanar rotational arc beams with the aid of multi-leaf(MLC) to provide beam collimation. Using the traditional Leksell Stereotactic System, the time to do a treatment in average was around 6 hours; however the workflow using a frameless system decreases the mean treatment time in less than an hour, turning out to be a resources optimization for its realization, all this with the help of all accessories, quality assurance that should be made before deliver a proper treatment. The goal of this study is to show our clinical experience doing frameless SRS, with VMAT technique in the treatment of Arteriovenous Malformations(AVMs), Brain Metastases, Meningiomas, among others. The issues discussed in this study with regard to not only the clinical features, but also beam characteristics, and dosimetric features. 20 patients have been treated since May up to September 2016 with different diagnostics, doses given are related to each pathology treated, each prescription isodose was higher than 96%. Frameless system used was trUpoint ARCH™ SRS/SRT System, the Immobilization is accomplished utilizing multiple immobilization components - custom head support, bite tray, thermoplastic mask, and nasion cushion - allowing a truly custom hold from CIVCO, Patients were simulated in Computed tomography (CT) simulation General Electric(GE) Optima model, slides acquisition 1.25 mm; Magnetic Resonance was also done in a Siemens de 1.5T with 1 mm slices in contrast enhanced T1 MPR, T2 Flair, T2 Ciss, Diffusion, Perfusion, DTI Tractography, Angiography was done in GE Discovery; for image fusion for PTV and OAR contouring; calculation were done in Monaco® planning system version 5.10.02 with Monte Carlo algorithms; treatment delivery were make in a LINAC Elekta Infinity™ with Agility™ head with 160 interdigitating leaves with 0.5 cm width at isocenter; positioning verification XVI versión 4.5.1 b141. Treatment Delivery time 22 +/- 1.30 minutes for VMAT. Mean Monitor Units (MU) were 3795; For each patient IGRT is made with 3 XVI (Cone Beam CT), Pre and Post Treatment, what makes the procedure safe, confortable and accurate. With regard to CIRTOG a 0.9825 was obtained in average and QA was made using the OCTAVIUS® 1000 SRS with a Gamma Index 3mm/3% over 96%. Data found in this study with regard to the 20 patients treated; suggest that Frameless arch design provides a secure hold with no surgical attachment to the patient, displacements are less than 1 mm of patient movement permitted during intrafraction immobilization testing; also is safe, confortable and easy to use even allows us to rapid response for anxious patients with its release mechanism. Less treatment times and also excellent clinical outcomes.
Read full abstract