We plan to measure the permanent electric dipole moment (EDM) of the elec- tron, which has the sensitivity to the CP violation in theories beyond the standard model by using the laser-cooled francium (Fr) atom. This paper reports the present status of the EDM measurement system. A high voltage application system was constructed in order to produce the strong electric field (100 kV /cm) needed for the experiment. After condi- tioning, the leakage current was 10 pA when a high voltage of 43 kV was applied. Also, a drift of an environmental field was measured at the planned location of the Fr-EDM experiment. The drift is suppressed at present down to the level of 10 pT by installing a 4-layer magnetic shield. Improvements are still needed to reach the required field stability of 1 fT.