It was discovered that reinforced concrete elevated water tanks with frame staging outperformed reinforced concrete elevated water tanks with shaft staging in terms of seismic resistance. These can be due to the frame staging's seismic energy absorption capability. As a result, the primary goal of this research is to better understand the seismic behavior and performance characteristics of elevated water tanks with frame staging. Furthermore, when compared to other shapes, circular tanks have the smallest surface area for a given tank size. As a result, the amount of material needed for a circular water tank is less than for other shapes. As a result, a circular water tank was chosen, and seismic analysis of elevated RC circular water tanks was carried out according to IITK-GSDMA guidelines, with the behavior of the water tank analysed for various parameters such as zone factor, soil condition, and different staging heights. SAP 2000 was used to determine the structure's modal characteristics (mode shapes and modal participation mass ratio).