Background contextAdolescent idiopathic scoliosis (AIS) necessitates accurate spinal curvature assessment for effective clinical management. Traditional two-dimensional (2D) Cobb angle measurements have been the standard, but the emergence of three-dimensional (3D) automatic measurement techniques, such as those using weight-bearing 3D imaging (WR3D), presents an opportunity to enhance the accuracy and comprehensiveness of AIS evaluation. PurposeThis study aimed to compare traditional 2D Cobb angle measurements with 3D automatic measurements utilizing the WR3D imaging technique in patients with AIS. Study design/settingA cohort of 53 AIS patients was recruited, encompassing 88 spinal curves, for comparative analysis. Patient sampleThe patient sample consisted of 53 individuals diagnosed with AIS. Outcome measuresCobb angles were calculated using the conventional 2D method and three different 3D methods: the Analytical Method (AM), the Plane Intersecting Method (PIM), and the Plane Projection Method (PPM). MethodsThe 2D cobb angle was manually measured by 3 experienced clinicians with 2D frontal whole-spine radiographs. For 3D cobb angle measurements, the spine and femoral heads were segmented from the WR3D images using a 3D-UNet deep-learning model, and the automatic calculations of the angles were performed with the 3D slicer software. ResultsAM and PIM estimates were found to be significantly larger than 2D measurements. Conversely, PPM results showed no statistical difference compared to the 2D method. These findings were consistent in a subgroup analysis based on 2D Cobb angles. ConclusionEach 3D measurement method provides a unique assessment of spinal curvature, with PPM offering values closely resembling 2D measurements, while AM and PIM yield larger estimations. The utilization of WR3D technology alongside deep learning segmentation ensures accuracy and efficiency in comparative analyses. However, additional studies, particularly involving patients with severe curves, are required to validate and expand on these results. This study emphasizes the importance of selecting an appropriate measurement method considering the imaging modality and clinical context when assessing AIS, and it also underlines the need for continuous refinement of these techniques for optimal use in clinical decision-making and patient management.