AP1000® Generation III+ reactor bases its safety concept on passive systems, differently from the previous Generation II reactors. This fact has led the approximations and methodologies previously used for modeling active safety systems to be reviewed and adapted to simulate the physics of passive systems. Diverse studies about the AP1000 containment have demonstrated the difficulty to correctly model the occurring phenomenology.In this paper, an integral AP1000 3D containment GOTHIC model is presented, including the Passive Containment Cooling System (PCCS). The model includes the compartments inside and outside the metallic containment liner that influence the thermal–hydraulic behavior. The model is tested against a Large Break Loss of Coolant Accident (LBLOCA) to assess its thermal–hydraulic performance, assuming a PCS tank malfunction, what is a conservative hypothesis. The pressure and temperature evolution predicted by the 3D containment model is analyzed and compared with a single node Lumped Parameters model, allowing to evaluate some preliminary benefits of 3D modeling for containment safety analysis.The 3D containment model allows to predict the thermal evolution in each containment compartment capturing the heterogeneity of this phenomenon, with higher resolution than the lumped parameters models traditionally used in this kind of analyses. It allows to observe the thermohydraulic conditions locally at any time during the transient.