To study the efficacy of the Jeti thrombectomy device in patients with acute DVT. 30 patients (10 male, 20 female) with mean age of 57 years (± 21 years) with acute lower extremity venous thrombosis were reviewed. The study was approved by the Institutional Review Board (IRB). The primary outcome measure was technical success, defined as reestablishment of inline flow. Secondary outcome measures were percent thrombus removal, total thrombolytic dose, total number of DVT-related procedures, total procedural time, overnight thrombolysis post procedure, ICU length of stay, total hospital length of stay, procedure-related complications. Additional data points included mean symptom duration and venous segments treated. A total of 40 procedures were performed in 30 patients. Technical success was 93.3% (28 of 30 patients). Mean percent thrombus removal was 74.0% (± 28.2%). Mean tPA dose was 7.8 mg (± 8.9 mg). Average number of DVT procedures was 1.3 (± 0.5). Mean procedural time was 88.7 mins (± 44.6 mins). 23 of 30 patients did not require overnight thrombolysis after Jeti thrombectomy. 12 of 30 patients did not require thrombolytics at all. Mean hospital length of stay was 4.9 days (± 5.2 days). Mean ICU length of stay was 1.6 days (± 4.6 days). In the patients who did not require overnight thrombolysis, mean percent thrombus removal was 81.2% (± 24.2%), mean tPA dose was 3.1 mg (± 3.8 mg) and mean ICU length of stay was 1.1 days (± 4.9 days). No major complications were observed. One minor complication included focal contrast extravasation, which was self-limiting. Mean symptom duration was 7.7 days (± 9.2 days). Venous segments included iliocaval (25), iliofemoral (20), femoropopliteal (15). The Jeti aspiration thrombectomy system offers a safe and feasible adjunct to currently available options for peripheral thrombectomy, allowing for significant potential reduction of thrombolytics and ICU length of stay. Further studies to evaluate the safety, efficacy, and cost-effectiveness of the system in the peripheral vasculature are warranted.