Abstract Computer simulation turns out to be beneficial when clinical data lack spatio-temporal resolution or parameters cannot be measured at all. To derive trustworthy results, these in-silico models have to thoroughly parameterized and validated. In this work we present data from a simplified in-vitro setup for characterizing ventricular electromechanics. Right ventricular papillary muscles from New Zealand rabbits were isolated and stretched from slack length to lmax , i.e. the muscle length at maximum active force development. Active stress development showed an almost linear increase for moderate strain (90–100% of lmax ) and a significant decrease for larger strain (100–105% of lmax ). Passive strain development showed a nonlinear increase. Conduction velocity CV showed an increase of ≈10% between low and moderate strain and no significant decrease beyond. Fitting active active stress-strain relationship using a 5th-order polynomial yielded adequate results for moderate and high strain values, whereas fitting using a logistic function yielded more reasonable results for low strain values. Passive stress-strain relationship was satisfactorily fitted using an exponential function.