Abstract NEMCA known for the increasing the catalytic activity/selectivity of the gas exposed electrodes was investigated for the potentiometric zirconia oxygen sensor activation. Electrochemical promotion of O2-sensors with Pt-cermet electrodes aged in the field was significant with up to 5 times in the impedance reduction. Stability test on the NEMCA activated °2 -sensors was showing just a minor impedance increase. Sensor response time was reduced by NEMCA effect by ~5-10% with up to 3 times signal noise reduction on the aged O2-sensors.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: International Journal on Smart Sensing and Intelligent Systems
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.