ABSTRACT In this work, the concentrations of malathion in fruits were determined using UV-Vis spectrophotometry prior to pre-concentration using QuEChERS. The Z-sep+/PSA sorbent combination was used for the d-SPE clean-up and extraction was done using acetonitrile during QuEChERS. The absorbance of malathion was measured using a UV-Vis spectrophotometer at a wavelength of 415 nm. The QuEChERS parameters, which included type and volume of extraction solvent, type and mass of sorbents, and centrifugation rate, were optimised prior to application of the developed method to real fruit samples. The linear range was from 0.1 to 0.9 mg kg−1 while the coefficient of determination (R2) was 0.9999. The limit of detection (LOD) for malathion was found to be 0.017 mg kg−1 and the limit of quantification was 0.05 mg kg−1. Orange samples were found to have no malathion residues when the developed method was applied to them while the concentrations of malathion in apple and pear samples were 0.07 mg kg−1 and 0.09 mg kg−1 respectively.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.