Abstract

The ENFSI (European Network of Forensic Science Institutes) DNA Working Group undertook a collaborative project on Y-STR typing of DNA mixture samples that were centrally prepared and thoroughly tested prior to the shipment. Four commercial Y-STR typing kits (Y-Filer, Applied Biosystems, Foster City, CA, USA; Argus Y Nonaplex, Biotype, Dresden, Germany; Powerplex Y, Promega, Madison, WI, USA; and DYSplex-3, SERAC, Bad Homburg, Germany) were used for the amplification of the mixture samples. The results of the study showed a striking inter-laboratory difference of kit performance as determined from the peak heights of the obtained Y-STR genotypes. Variation in quantity and quality of the shipped DNA can be excluded as reason for the observed differences because both samples and shipping conditions were found to be reproducible in an earlier study. The results suggest that in some cases a laboratory-specific optimization process is indicated to reach a comparable sensitivity for the analysis of minute amounts of DNA.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.