Abstract

Silicon pore optic (SPO) mirror modules (MMs) are being developed and produced for ESA’s ATHENA mission. The optics have, and will be, tested at MPEs PANTER x-ray test facility. We present the results obtained from tests performed at the PANTER x-ray test facility for the SPO MM-0050 that was produced to verify the latest optical performance (half energy width (HEW), effective area) of SPOs, supporting the ESA reviews of their optical performance. <br/> The preparations are ongoing at PANTER, ESA, cosine and Media Lario to perform complex opto-thermo-mechanical tests of the two full scale 1/6th sectors of the final ATHENA mirror assembly structure produced by the potential ATHENA primes Airbus Defence and Space and Thales Alenia Space. For these tests a set of three SPO MMs have been produced following the flight configuration. The MMs will be incorporated into the full scale 1/6th sectors to measure the impact of thermal gradients on the thermoelastic deformation of the structure and therefore the HEW performance. A description of the tests is presented here. <br/> PANTER is also involved in the development, testing, and fabrication of the mirror adapter structure (MAS) to support the 2.6-m diameter ATHENA mirror assembly module demonstrators (MAMD) during the planned x-ray tests at XRCF. A description of the PANTER tests and results will be presented in this paper together with a short overview of the MAS MGSE for XRCF.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call