Abstract

Methods are presented for the determination of the vertical extension and divergence of electron beams in storage rings which also allow to obtain the vertical emittance. The ver-tical extension of the electron beam of the storage ring BESSY was measured with an X-ray slit camera. The vertical divergence was derived from the vertical angular distribution of the synchrotron radiation of the storage ring measured with either an X-ray polarimeter or an energy dispersive X-ray photon counter.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.