Abstract
X-ray computed tomography (XCT) is uniquely suitable for non-destructive dimensional measurements of delicate or internal features produced, for example, by additive manufacturing. While XCT has long been used in medical imaging, it has been used for industrial dimensional measurements only in recent years. The error sources in XCT of industrial components is still a topic of active research. One subgroup of potential error sources in XCT measurements are uncorrected XCT instrument geometry errors, such as detector misalignment or rotation stage errors, and are the focus of this paper. We demonstrate the effect of some instrument geometry errors on measurements performed on a calibrated artifact and compare the results to those obtained through simulations. The overall objective of this work is to support ongoing efforts to develop documentary national and international standards for performance evaluations of XCT instruments. In this study, we focus on cone-beam XCT instruments.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.