Abstract

In forensic pathology, it is important to detect and recover as evidence residual metal particles and projectiles when evaluating potential gunshot wounds. This process can be challenging when the bullets are fragmented. This report presents our experience using multiple modalities to analyze the wound of an illegally killed Japanese serow (Capricornis crispus) found in a mountainous region without its head and hind limbs. We performed postmortem computed tomography (PMCT) and necropsy that showed a distant-range gunshot wound of the neck likely created by a centerfire rifle. A postmortem cut through the neck and absent head precluded a complete evaluation. To determine the composition of the metal-like fragments in the neck, sampling and metal analysis were performed in two ways. Samples extracted from the exposed wound surface without CT guidance were analyzed directly using inductively coupled plasma mass spectrometry (ICP-MS). Samples from the bone, muscles, and cervical cord extracted under CT guidance were analyzed using x-ray analytic microscopy (XGT-9000, HORIBA, Kyoto, Japan). In wound surface samples, silicon and iron were detected as the main components on ICP-MS, suggesting that the materials were gravel. The samples taken under CT guidance and analyzed with XGT-9000 revealed that the high-density CT areas were mainly composed of lead. Combining CT-guided sample extraction and XGT-9000 can be useful for retrieving true projectile fragments and avoiding the confusion created by erroneously sampling non-projectile surface materials.