Abstract

Three different Ti alloys of biomedical interest have been studied by means of X-ray photoelectron spectroscopy (XPS) to determine their surface chemical composition in both as-received condition and after oxidation at 750 °C in air for different times. Compositions of the investigated alloys were, in wt.%, Ti–7Nb–6Al, Ti–13Nb–13Zr and Ti–15Zr–4Nb. XPS analyses showed a behaviour of the Ti–7Nb–6Al alloy different from that of the two TiNbZr alloys, evidencing the role of the chemical composition of the alloys on the oxidation mechanisms. The oxidation process generates an aluminium-oxide rich surface on the Ti–7Nb–6Al, while in the case of the TiNbZr alloys a titanium-oxide rich layer is formed. The effect of the heat treatment on the contribution of the minority elements at the surface is also discussed.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.