Abstract

This paper proposes a novel one-colour Xe–Kr laser induced collisional ionization system. Considering the level scheme of the system, it finds that the initial state of the reaction–the four 4f levels with even J of Xe–can be prepared through method of four-photon resonant excitation by dye laser with wavelength of ∼440 nm. Absorption of an additional photon (the transfer laser) of the same wavelength will complete the laser induced collisional ionization process. The resonance enhanced ionization spectrum of Xe by four laser photons at ∼440 nm is measured through time-of-flight mass spectrometry, this aims at the preparation of the initial state of the system proposed. The Stark broadening of the measured spectrum is observed and consistent with the previous study. Analysis of the measured resonance ionization spectrum implies the feasibility of ∼440 nm four-photon resonant excitation of the initial 4f state of the Xe–Kr system proposed in this paper, which prepares for a further experiment of laser induced collisional ionization.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.