Abstract

Silicon and Teflon substrates have been structured by wet etching and a focused ion beam (FIB) to obtain very defined, clean apertures. Planar, free-standing lipid membranes (black lipid membranes (BLM)) with enhanced long-term stability have been prepared on these apertures by the methods of Montal and Müller(1,2) as well as Müller and Rudin.(3) The stability and geometric control enables the use of X-ray analysis of free-standing single bilayers. With the presented setup, simultaneous structural and electrophysiological measurements will become feasible.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.