Abstract

We have developed an improved method of time-resolved x-ray reflectivity (XRR) using monochromatic synchrotron radiation. Our method utilizes a polycapillary x-ray optic to create a range of incident angles and an area detector to collect specular reflections. By rotating the sample normal out of the plane of the incident fan, we can separate the surface diffuse scatter from the reflectivity signal, greatly improving the quality of the XRR spectra compared to previous implementations. We demonstrate the time-resolved capabilities of this system, with the temporal resolution as low as 10 ms, by measuring XRR during the annealing of Al/Ni nano-scale multilayers, and use this information to extract the activation energy for interdiffusion in this system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.