Abstract

AbstractThe oxide chemical composition on metallic Ni and NiCr alloy electrodes has been studied for changes in simulated reactor coolant solution chemistry, through a range of oxidizing potentials and pH settings at 25 °C and 150 °C. Even under strongly reducing conditions, the Ni surface has a 2‐nm layer of oxide and hydroxide from which further oxides form, depending on the subsequent oxidative step. For basic (normal operating) pH conditions and under oxidation potentials near 0 volts (vs. SCE), a predominantly Ni(OH)2 layer is formed that appears to remain relatively stable up to at least 48 hours of oxidation at 150 °C. For the NiCr alloy, similar stability is imparted by a thin film of Cr(OH)3/ Cr2O3 and Ni(OH)2./NiO. Under milder oxidizing (but still basic) conditions, the surface is stabilized by a thin film that is mostly Ni(OH)2/NiO. Under neutral solution conditions, the same oxide/ hydroxide films do not seem to be as effective in stabilizing the surface. Copyright © 2017 John Wiley & Sons, Ltd.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.