Abstract

Measurements of intrinsic conductivity and X-ray induced conductivity were performed on specially undoped ZnSe samples. The measurements demonstrated that sensors made of ZnSe have minor intrinsic conductivity when heating up to the temperature of 180 °C, and significant X-ray induced conductivity. Dose dependence “dose rate – current” is described with simple power function which considerably simplifies calibration of sensors. This results can be used during the designing of high-temperature X-ray and gamma-radiation detectors for radiation hot rolling thickness gauges which are widely used in the metallurgy.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.