Abstract

A first focusing test of the undulator radiation at SPring-8 has been done using two types of x-ray refractive lenses in thin glass capillaries. One (lens No. 1) contained bubbles in a glue whereas the other (lens No. 2) contained bubbles in glycerol. The capillaries had inner diameters of 0.2 and 0.8 mm, respectively. Using x rays of 17–18 keV, the undulator source image was investigated at the focal plane. The spherical aberrations and the field distortions were carefully examined by taking the images of a gold mesh. Lens No. 1 had an advantage of high transmissivity in the hard x-ray region (18% at 18 keV) and high tolerance to severe radiation damage, e.g., ∼5×1012 photons/s/0.03 mm2 of the 18 keV x rays for an exposure time of 1 h. On the other hand, lens No. 2 had an advantage of a large aperture, 0.8 mm, and a small field distortion, e.g., less than 10% inside a diameter of 300 μm.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call