Abstract

In the operation of high-voltage hydrogen thyratrons, the bombardment of the anode by high-energy electrons causes the production of X-rays. The X-ray output of three types of high-voltage hydrogen thyratrons has been studied to determine the generation of X-rays as a function of the operating parameters. The beam pattern and the energy and intensity of the emitted X-rays are included. It has been determined that emission occurs during the breakdown of the pulse and during the interpulse interval as a result of grid emission. The beam pattern is defined by the geometry of the tube and is a narrow beam emanating in a circle from the grid-anode region. Values for the X-ray energy and intensity and for protective shielding are given.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.