Abstract
Dose profiles in teeth have been experimentally and theoretically studied for different energies and geometries of incident X- and gamma-rays. The experiments were conducted with teeth inside of an Alderson phantom using monodirectional radiation beams at selected energies; they revealed two effects: an apparent lack of dose attenuation between the buccal and the lingual sides of the teeth for energies higher than 120 keV and an attenuation between first and last tooth layers for low-energy beams in the range from 0.28 to 0.57. Monte Carlo simulations confirmed the experimental data and provided dose profiles for other energies and geometries. In particular, exposure in the rotational radiation field produces pronounced dose profiles only for energies lower than 60 keV. The usefulness of these data to estimate the average energy of accidental radiation field is discussed.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.