Abstract

Time-lapse X-ray computed microtomography was employed to quantify the deformation behaviour of closed-cell aluminium foam. The specimen was incrementally loaded and tomographically scanned using a custom X-ray tomographic device to capture the deforming microstructure. Because of the very small thickness of the cell walls and the high ratio between pore size and cell wall thickness cone-beam reconstruction procedure was applied. A finite element (FE) model was developed based on the reconstructed three-dimensional data. The FE model was used for two purposes: i) the nodal points were used for tracking the displacements of the deforming structure, ii) verification of the material model for description of the foam's deformational behaviour. Digital volumetric correlation (DVC) algorithm was used on data obtained from the time-lapse tomography to provide a detailed description of the evolution of deformation in the complex structure of aluminium foam. The results from DVC demonstrate the possibility to use the complex microstructure of the aluminium foam as a random pattern for the correlation algorithm. The underlying FE model enables easy comparison between experimental results and results obtained from numerical simulations used for evaluation of proposed constitutive models.

Full Text
Published version (Free)