Abstract

Responses to 1.8 MeV proton irradiation and 10-keV X-ray irradiation under typical bias conditions are investigated for AlGaN/GaN HEMTs fabricated with different types of process technologies. We find that, in contrast to previous generations of process technologies, total ionizing dose effects can be significant in these devices. For proton irradiation, worst-case bias for transconductance degradation for GaN-on-SiC substrate devices is ON bias, and for devices built on free-standing GaN substrates, the worst-case bias condition is semi-ON bias. Low-frequency noise measurements demonstrate that these differences result from differences in defect types and energy distributions for the different types of devices, both before and after irradiation. These results emphasize the need to test devices under a wide range of conditions during characterization and qualification testing.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.