Abstract

In early 1988, Simpson Paper Company installed the world’s first GE LM5000 cogeneration plant with full high and low pressure steam injection. The full STIG LM5000 achieves a dramatic power increase (from 32.5 MW to 49.5 MW) and remarkable improvements in efficiency from 36 to 43 percent, while reducing NOx emissions from 225 to less than 25 ppmv before further reduction with SCR. The plant, installed at Ripon, CA, features: (1) 130,000 lb/hr (59,000 kg/h) of steam injection at three locations on the gas turbine; (2) the first-time use of SCR with the STIG LM5000 resulting in an ultimate NOx emission rate of 6-13 ppmv; (3) a unique feedwater heat exchanger arrangement to reduce boiler stack temperature to 250°F (121°C); and (4) an innovative submicron inlet air filtration system to minimize the need for compressor washing. The details of cycle selection, design, installation, performance, and economic benefits of this first full STIG installation provide a useful insight into the potential of a flexible new technology.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.