Abstract

The patterns and extent of exposure to rosin based solder flux fume have been investigated in two surveys and a number of individual site visits carried out by the UK Health and Safety Executive (HSE). Determination of solder fume was by measurement of airborne resin acid participate. Both static and personal sampling was carried out over time periods ranging from 15 minutes to several hours. Resin acid concentrations were found to vary from less than 1 μg m−3 to 2289μg m−3. The effects of various types of local exhaust ventilation on resin acid concentrations have been observed. On-too I tip extraction systems were generally found to be the best control measure available; however good design, positioning and system maintenance is essential for efficient capture of the fume. The resin acid concentrations detected at these twenty-six sites suggest that the proposed British long and short term occupational exposure limits are realistically attainable targets, particularly where good working practices and/or effective fume control measures are in place.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.