Abstract

This study evaluated performance of individuals exercising at a fixed workload and wearing full-facepiece respirators modified to provide expiratory resistances of 0.27, 0.47, 1.81, 4.43, and 12.27 cmH20 x s x L(-1). On five separate occasions, 15 volunteers exercised to voluntary endpoint on a treadmill at fixed speeds and grades chosen to elicit 85% of maximal aerobic capacity for an unencumbered condition. Exercise performance time was recorded at the cessation of each test. Results showed that performance time decreased linearly (R2 = 0.79; p<0.001) with increased resistances, and no threshold value below which expiratory resistance has no impact on performance was found. Average oxygen consumption rates and minute ventilation also decreased linearly with increased expiratory resistances, indicating that increases in expiratory resistance result in a considerable level of hypoventilation. From the perspective of respirator design, the results of this study suggest that the only practical expiratory resistance level limitation is the reduction in performance that will be acceptable to the end users.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.