Abstract
A work function of 2.36 eV and a Richardson constant of 120 A/cm2 K2 have been measured for a hot-pressed porous lanthanum hexaboride rod cathode. It is shown that the LaB6 work function is highly susceptible to poisoning by molybdenum deposited at high temperatures during experiments. A stable work function of about 2.7 eV is then measured. After removal of the molybdenum by atomic iodine flux, the work function of clean LaB6 is restored.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.