Abstract

Abstract A study of wood dust exposure at furniture factories in one county in Denmark was performed as a cross sectional study. Dust exposure was measured with personal passive dust monitors and calibrated against active sampling on filters. Measurements of 1685 workers were included in the exposure assessment. The passive dust monitor conversion models for equivalent concentrations of inhalable dust and total dust based on data from the present study were not significantly different from the original models. Therefore models based on all available data were used. The parameters of the distribution of equivalent concentration of inhalable dust were 0.94 mg/m3 (geometric mean) and 2.10 (geometric standard deviation). Compared with a national cross sectional study from 1988 the exposure level (geometric mean) was reduced by a factor 2.0. Inhalable dust exposure was about 50% higher than exposure measured by the Danish ‘total’ dust method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.