Abstract A comparative study on seismic resistance of a structure on slopes with infill shear wall carried out on residential working by considering the gravity lords and lateral loads as Earthquake loads and Wind loads incorporating the shear walls to reduce the lateral power impact on structural individuals. The structure situated in sloping territories are especially progressively inclined to seismic condition in contrast with the structures that are arranged in level ground. Because of the inclining ground the section stature varies as short and long segments. Henceforth the huge measure of parallel power is pulled in by short segment because of its higher solidness. It prompts extreme harm to structure and causes loss of human life and property. Subsequently to expand the seismic presentation of expanding on inclining ground the shear dividers assume exceptionally essential job. Subsequently in this investigation the endeavor is made to break down the skyscraper structures on normal and inclining ground having and not having shear dividers. A G + 15 skyscraper having with various ground slopes varying from as 0°, 10°, 20° and 30° having shear walls and including shear walls at center four sides, at corner and giving total outside dividers shear divider have been considered for the examination. The structure proposed is designed by Limit State Method according to IS: 456-2000, the wind load analysis according to IS: 875-(part-3) 2015 and seismic loads according to IS: 1893(part-1) 2016. Shear divider examination as indicated by IS: 13920-2016.