Abstract

In this article, we propose a strategy for the design of a wireless power transfer system consisting of a class-E inverter, a half-bridge class-DE rectifier, and two coupled coils. The system is optimized for maximum power transfer efficiency. The design is validated via a case study, for which a wireless power transfer link to a neuroprosthesis was designed. After circuit simulations, a prototype was realized and measured. There is a good agreement between the calculated, simulated and measured voltages and currents. The prototype delivers <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\text {80}}$</tex-math></inline-formula> mW, <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\text {7}}$</tex-math></inline-formula> V to a biomedical implant at <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\text {6.78}}$</tex-math></inline-formula> MHz, the transfer efficiency is <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\text {52}}$</tex-math></inline-formula> to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\text {68\%}}$</tex-math></inline-formula> , depending on the alignment. The end-to-end efficiency, with the controller and gate driver also taken into account, is <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\text {39}}$</tex-math></inline-formula> to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\text {57\%}}$</tex-math></inline-formula> . Electromagnetic and thermal simulations were performed to verify compliance with relevant safety regulations on specific absorption rate (SAR) levels, magnetic field strength, and heat generation in the implant, for separation distances between the coils of <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\text {8}}$</tex-math></inline-formula> to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\text {15}}$</tex-math></inline-formula> mm, and transverse misalignment from <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">${\text {0}}$</tex-math></inline-formula> to <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\text {15}$</tex-math></inline-formula> mm.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call