Abstract

Recent problems with grouted posttensioning tendons in U.S. bridges have led to interest in tendons that are not grouted, but rather filled with a pliable corrosion protection system such as grease or wax. The use of a flexible filler material in place of cementitious grout results in an unbonded tendon, which not only affects the structural behavior but also enables the application of new methods for improved monitoring and maintenance. This paper outlines a novel continuous monitoring approach that aims to detect wire breakage in unbonded tendons based on relative strain variation in the anchor head (or wedge plate). The feasibility of the method is investigated using a finite-element model calibrated with experimental data from a seven-strand anchor head. The model is subsequently extended to a 19-strand anchor head to assess the method’s performance on detection, localization, and quantification of tendon damage. The numerical results confirm the correlation between wire breakage and relative strain variation among the monitoring points and illustrate the method’s effectiveness in determining the location and severity of damage.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.