Abstract

AbstractThe roof-to-wall connection in a house is designed to transfer the uplift and lateral loads during strong winds by providing a continuous load path from the roof to the foundation. The uplift capacity and failure mode of the connection depends on the number and type of fasteners (nails), timber species, type of framing anchor, and constructions defects. This paper presents experimental results that were used to assess the uplift capacity variation of typical roof-to-wall connections. Based on tests with two types of connections (triple grip and truss grip) assembled with two types of timber (radiata pine and spruce pine), nails (hand and gun), and framing anchors (triple grip and universal triple grip), the results show that the variation in timber species, nail, and triple grip type changes the strength and the failure modes of the connection. The strength of the connection was reduced by about 24% when the timber species was changed from radiata pine to spruce pine and the hand nail to gun nail ...

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.