Abstract

The present paper aims to enable the assessment of the fatigue damage of wind turbine blades over a long duration (e.g., several months/years) in conjunction with different operating regimes and based on two information sources: the 10-min SCADA data and an interpolation using response surfaces identified using the FAST aeroelastic numerical tool. To assess blade damage, prior studies highlighted the need for a high-frequency (>1 Hz) sampling rate. Because of data availability and computation resource limitations, such methods limit the duration of the analysis period, making the direct use of such an approach based on a 1 Hz wind speed signal in current wind farms impractical. The present work investigates the possibility of overcoming these issues by estimating the equivalent damage using a 1 Hz wind speed for each 10-min sample stored in the SCADA data. In the literature, the influence of operating regimes is not considered in fatigue damage estimation, and for the first time, the present project takes a pioneering approach by considering these operating regimes.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.