Abstract

AbstractWind loads are generally divided into along-wind, across-wind, and torsional loads, but in reality they occur simultaneously in time and space. Furthermore, because they do not show their maximums at the same instant, they need to be combined appropriately. In this study, pressure measurements were conducted on atypical supertall buildings to investigate wind load combinations. Using a simplified reference model with four columns, analyses in the time domain were conducted, and this paper proposes combination rules based on the concept of combination factor that can be applied to atypical supertall buildings. The combination factor for a square model is approximately 0.5, and those for atypical models differ depending on building shape. Two methods are discussed in the determination of combination factors, and comparisons between peak normal stresses by analysis and combination factor show relatively good agreement, ranging mostly within ±5%.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.